PURGE VALVE INSPECTION

PROCEDURE

  1. INSPECT PURGE VSV

    1. A211313E01

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection

      Condition

      Specified Condition

      1 - 2

      20°C (68°F)

      23 to 26 Ω

      1 - VSV body

      Always

      10 MΩ or higher

      2 - VSV body

      Always

      10 MΩ or higher

      If the result is not as specified, replace the purge VSV.

    2. Check the operation of the purge VSV.

      1. A211314E02

        Check that air does not flow from port E to port F.

      2. A211315E02

        Apply battery voltage to terminals 1 and 2.

      3. Check that air flows from port E to port F.

        If the result is not as specified, replace the purge VSV.