AIR CONDITIONING SYSTEM(for Manual Air Conditioning System) IG Power Source Circuit
| DTC Code | DTC Name |
|---|---|
| IG Power Source Circuit |
DESCRIPTION
The main power source is supplied to the air conditioning amplifier assembly when the ignition switch is turned to ON. The power source is used for operating the air conditioning amplifier assembly, servo motors, etc.
WIRING DIAGRAM
CAUTION / NOTICE / HINT
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
Start the engine before inspection. Check the relays, fuses and battery if the engine does not start.
PROCEDURE
CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - BATTERY AND BODY GROUND)
-
Disconnect the H118 amplifier connector.
Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection
Switch Condition
Specified Condition
H118-1 (IG+) - Body ground
Ignition switch off
Below 1 V
Ignition switch ON
11 to 14 V
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
H118-23 (GND) - Body ground
Always
Below 1 Ω
Table 1. Text in Illustration *1
Front view of wire harness connector
(to Air Conditioning Amplifier Assembly)
REPAIR OR REPLACE HARNESS OR CONNECTOR
-