DESCRIPTION
This circuit is the power source circuit for the meter. This circuit provides two types of power sources; one is a constant power source, and the other is an IG power source.
WIRING DIAGRAM
| *a | from Auxiliary Battery |
| *b | from IG2 Relay |
| *c | Combination Meter Sub-assembly |
CAUTION / NOTICE / HINT
Note
Inspect the fuses of circuits related to this system before performing the following inspection procedure.
PROCEDURE
CHECK HARNESS AND CONNECTOR (COMBINATION METER SUB-ASSEMBLY CIRCUIT)
| *a | Front view of wire harness connector (to Combination Meter Sub-assembly) |
Disconnect the L27 combination meter sub-assembly connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
| Result | Proceed to |
|---|---|
| OK (w/o Multi-information display) | A |
| OK (w/ Multi-information display) | B |
| NG | C |
| A |
|
REPLACE METER CIRCUIT PLATE Click here |
| B |
|
REPLACE COMBINATION METER SUB-ASSEMBLY Click here |
| C |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |