BLIND SPOT MONITOR SYSTEM, Diagnostic DTC:C1AB7
| DTC Code | DTC Name |
|---|---|
| C1AB7 | Blind Spot Monitor Slave Module |
DESCRIPTION
This DTC is stored when the blind spot monitor sensor RH detects an internal malfunction.
DTC No. |
Detection Item |
DTC Detection Condition |
Trouble Area |
|---|---|---|---|
C1AB7 |
Blind Spot Monitor Slave Module |
The blind spot monitor sensor RH (slave) detects an internal malfunction. |
Blind spot monitor sensor RH |
CAUTION / NOTICE / HINT
Note:
When checking for DTCs, make sure that the blind spot monitor system is on.
PROCEDURE
CHECK DTC
Clear the DTCs.
Body Electrical > Blind Spot Monitor Slave > Clear DTCs
Recheck for DTCs and check if the same DTC is output again.
Body Electrical > Blind Spot Monitor Slave > Trouble Codes
Result
Result
Proceed to
No DTCs are output
A
DTCs are output
B