MULTI-MODE MANUAL TRANSAXLE SYSTEM, Diagnostic DTC:P0820
| DTC Code | DTC Name |
|---|---|
| P0820 | Gear Lever "X-Y" Position Sensor Circuit |
DESCRIPTION
The TCM detects the shift lever position using the shift lever position sensor. The shift lever position sensor has two functions; detection and monitoring.
The shift lever position sensor consists of the Link 1 circuit that detects the shift lever positions, R, N, E and M, and the Link 2 circuit that detects the "+" and "-" positions. The circuits are connected to the shift lever via the respective links. The contact switches (6-contact switch for Link 1, and 2-contact switch for Link 2) of the circuits turn on and off in accordance with the fore-aft movement of the shift lever. The TCM detects the current shift lever position in accordance with the ON/OFF status of these contact switches. The transmission shift main switch detects the side-to-side movement of the shift lever. It turns off when the shift lever is in R, N, or E , and turns on when in M, "+", or "-" .
The shift lever position sensor and the transmission shift main switch convert the shift lever position into electric signals and output them to the TCM. The TCM detects the current shift lever position from these signals and operates the actuators to change the gear position.
Contact Point |
Shift Lever Position |
||||||
R |
N |
E |
M |
- |
+ |
||
Link 1 |
LSRC |
OFF |
ON |
ON |
ON |
ON |
ON |
LSWR |
ON |
OFF |
OFF |
OFF |
OFF |
OFF |
|
LSSC |
ON |
ON |
OFF |
OFF |
OFF |
OFF |
|
LSWS |
OFF |
OFF |
ON |
ON |
ON |
ON |
|
LSNC |
ON |
OFF |
ON |
ON |
ON |
ON |
|
LSWN |
OFF |
ON |
OFF |
OFF |
OFF |
OFF |
|
Link 2 |
LSW- |
OFF |
OFF |
OFF |
OFF |
ON |
OFF |
LSW+ |
OFF |
OFF |
OFF |
OFF |
OFF |
ON |
|
Transmission Shift Main Switch |
OFF |
OFF |
OFF |
ON |
ON |
ON |
|
The monitor runs when the shift lever is moved through each position (N, R, E, M, - and +).
DTC No. |
Detection Item |
DTC Detection Condition |
Trouble Area |
MIL |
Warning Indicate |
Memory |
|---|---|---|---|---|---|---|
P0820 |
Gear Lever "X-Y" Position Sensor Circuit |
The TCM detects one of the following conditions: (1-trip detection logic)
The TCM detects one of the following conditions: (1-trip detection logic)
The TCM detects one of the following conditions: (1-trip detection logic)
The TCM detects the following conditions simultaneously: (1-trip detection logic)
|
|
Does not come on |
Comes on |
DTC stored |
WIRING DIAGRAM
PROCEDURE
READ VALUE USING GTS (SHIFT LEVER SWITCH AND SHIFT LEVER CHECK SIGNAL)
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Powertrain / Multi-Mode M/T / Data List / Shift Lever Switch Signal 1 - 5, and Shift Lever Check Signal 1 - 3.
Check that the normal condition specified in the following table is shown on the display when moving the shift lever to each position R, N, E, M, "+" , and "-".
Powertrain > Multi-Mode M/T > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Shift Lever Switch Signal1
Shift lever switch signal "+"
OFF or ON
OFF: Shift lever not in "+"
ON: Shift lever in "+"
LSW1 (LSW+) terminal signal of TCM
Shift Lever Switch Signal2
Shift lever switch signal R
OFF or ON
OFF: Shift lever not in R
ON: Shift lever in R
LSW2 (LSWR) terminal signal of TCM
Shift Lever Switch Signal3
Shift lever switch signal M or E
OFF or ON
OFF: Shift lever in R or N
ON: Shift lever in E, M, "+" or "-"
LSW3 (LSWS) terminal signal of TCM
Shift Lever Switch Signal4
Shift lever switch signal N
OFF or ON
OFF: Shift lever not in N
ON: Shift lever in N
LSW4 (LSWN) terminal signal of TCM
Shift Lever Switch Signal5
Shift lever switch signal "-"
OFF or ON
OFF: Shift lever not in "-"
ON: Shift lever in "-"
LSW5 (LSW-) terminal signal of TCM
Shift Lever Check Signal1
Check signal of shift lever switch signal 2
OFF or ON
OFF: Shift lever in R
ON: Shift lever not in R
LS2C (LSRC) terminal signal of TCM
Reversal signal of LSW2 (LSWR) (ON and OFF reversed)
Shift Lever Check Signal2
Check signal of shift lever switch signal 3
OFF or ON
OFF: Shift lever in E, M, "+" or "-"
ON: Shift lever in R or N
LS3C (LSSC) terminal signal of TCM
Reversal signal of LSW3 (LSWS) (ON and OFF reversed)
Shift Lever Check Signal3
Check signal of shift lever switch signal 4
OFF or ON
OFF: Shift lever in N
ON: Shift lever not in N
LS4C (LSNC) terminal signal of TCM
Reversal signal of LSW4 (LSWN) (ON and OFF reversed)
Powertrain > Multi-Mode M/T > Data List
Tester Display
Shift Lever Switch Signal1
Shift Lever Switch Signal2
Shift Lever Switch Signal3
Shift Lever Switch Signal4
Shift Lever Switch Signal5
Shift Lever Check Signal1
Shift Lever Check Signal2
Shift Lever Check Signal3
OK
When the shift lever is operated, the normal condition listed above is shown on the GTS.
Result
Proceed to
OK
NG
INSPECT SHIFT LOCK CONTROL UNIT ASSEMBLY (SHIFT LEVER POSITION SENSOR)
Disconnect the shift lever position sensor connector.
Measure the resistance according to the value(s) in the table below.
Tip:The shift lever position sensor connector has no terminals in locations of 1, 8, 7, and 14.
Standard Resistance
Tester Connection
Condition
Specified Condition
2 (LSRC) - 3 (LSWS)
Shift lever in E, M, "+" or "-"
Below 1 Ω
2 (LSRC) - 13 (LSNC)
Below 1 Ω
3 (LSWS) - 4 (COM1)
Below 1 Ω
3 (LSWS) - 11 (COM2)
Below 1 Ω
2 (LSRC) - 4 (COM1)
Shift lever in N, E, M, "+" or "-"
Below 1 Ω
2 (LSRC) - 11 (COM2)
Below 1 Ω
2 (LSRC) - 6 (LSWN)
Shift lever in N
Below 1 Ω
2 (LSRC) - 10 (LSSC)
Below 1 Ω
4 (COM1)- 6 (LSWN)
Below 1 Ω
6 (LSWN) - 10 (LSSC)
Below 1 Ω
6 (LSWN) - 11 (COM2)
Below 1 Ω
4 (COM1) - 5 (LSW+)
Shift lever in "+"
Below 1 Ω
5 (LSW+) - 11 (COM2)
Below 1 Ω
4 (COM1) - 9 (LSWR)
Shift lever in R
Below 1 Ω
9 (LSWR) - 10 (LSSC)
Below 1 Ω
9 (LSWR) - 11 (COM2)
Below 1 Ω
9 (LSWR) - 13 (LSNC)
Below 1 Ω
10 (LSSC) - 13 (LSNC)
Below 1 Ω
4 (COM1) - 10 (LSSC)
Shift lever in R or N
Below 1 Ω
10 (LSSC) - 11 (COM2)
Below 1 Ω
4 (COM1) - 11 (COM2)
Always
Below 1 Ω
4 (COM1) - 12 (LSW-)
Shift lever in "-"
Below 1 Ω
11 (COM2) - 12 (LSW-)
Below 1 Ω
4 (COM1) - 13 (LSNC)
Shift lever in R, E, M, "+" or "-"
Below 1 Ω
11 (COM2) - 13 (LSNC)
Below 1 Ω
Result
Proceed to
OK
NG
CHECK HARNESS AND CONNECTOR (TCM - SHIFT LEVER POSITION SENSOR)
Disconnect the TCM connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
E104-11 (LS4C) - E102-13 (LSNC)
Always
Below 1 Ω
E104-12 (LS3C) - E102-10 (LSSC)
Always
Below 1 Ω
E104-13 (LS2C) - E102-2 (LSRC)
Always
Below 1 Ω
E104-15 (LSW5) - E102-12 (LSW-)
Always
Below 1 Ω
E104-16 (LSW4) - E102-6 (LSWN)
Always
Below 1 Ω
E104-17 (LSW3) - E102-3 (LSWS)
Always
Below 1 Ω
E104-18 (LSW2) - E102-9 (LSWR)
Always
Below 1 Ω
E104-19 (LSW1) - E102-5 (LSW+)
Always
Below 1 Ω
E104-11 (LS4C) - Body ground
Always
10 kΩ or higher
E104-12 (LS3C) - Body ground
Always
10 kΩ or higher
E104-13 (LS2C) - Body ground
Always
10 kΩ or higher
E104-15 (LSW5) - Body ground
Always
10 kΩ or higher
E104-16 (LSW4) - Body ground
Always
10 kΩ or higher
E104-17 (LSW3) - Body ground
Always
10 kΩ or higher
E104-18 (LSW2) - Body ground
Always
10 kΩ or higher
E104-19 (LSW1) - Body ground
Always
10 kΩ or higher
Result
Proceed to
OK
NG
NG REPAIR OR REPLACE HARNESS OR CONNECTOR
CHECK HARNESS AND CONNECTOR (SHIFT LEVER POSITION SENSOR - BODY GROUND)
-
*a
Front view of wire harness connector
(to Shift Lever Position Switch)
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
E102-4 (COM1) - Body ground
Always
Below 1 Ω
E102-11 (COM2) - Body ground
Always
Below 1 Ω
Result
Proceed to
OK
NG
NG REPAIR OR REPLACE HARNESS OR CONNECTOR
-
REPLACE TCM
Replace the TCM.
Result
Proceed to
NEXT
PERFORM INITIALIZATION
Perform the initialization and learning procedure.
Result
Proceed to
NEXT
NEXT END