REVOLUTION SENSOR INSPECTION
PROCEDURE
INSPECT TRANSMISSION REVOLUTION SENSOR (NIN)
-
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
1 (NIN-) - 2 (NIN +)
20°C (68°F)
560 to 680 Ω
If the result is not as specified, replace the transmission revolution sensor (NIN).
Table 1. Text in Illustration *a
Component without harness connected
(Transmission Revolution Sensor (NIN))
-
INSPECT TRANSMISSION REVOLUTION SENSOR (NOUT)
Wave a magnetic object left and right in front of the transmission revolution sensor (NOUT) tip (5 mm (0.197 in.) or less) to change the high/low signals while measuring the current.
Table 2. Text in Illustration *1
Battery
-
-
*a
Component without harness connected
(Transmission Revolution Sensor (NOUT))
*b
Magnet
*c
5 mm (0.197 in.) or less
*d
Ammeter
Note:Make sure to wave the magnetic object during the inspection. Current will not change without waving the magnetic object as indicated by the arrow in the illustration.
Measure the current according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
1 (NOTO) - 2 (NOTB)
Low signal
4 to 8 mA
High signal
12 to 16 mA
If the result is not as specified, replace the transmission revolution sensor (NOUT).