BACK-UP LIGHT SWITCH INSPECTION

PROCEDURE

  1. INSPECT BACK-UP LIGHT SWITCH ASSEMBLY

    C162847C03

    *a

    Push

    *b

    Release

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection

      Switch Condition

      Specified Condition

      1 - 2

      Pushed

      Below 1 Ω

      1 - 2

      Released

      10 kΩ or higher

      If the result is not as specified, replace the back-up light switch assembly.