PROCEDURE
RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM
for HFC-134a (R134a):
for HFO-1234yf (R1234yf):
SEPARATE SUCTION HOSE SUB-ASSEMBLY
SEPARATE AIR CONDITIONER TUBE AND ACCESSORY ASSEMBLY
REMOVE COOLER EXPANSION VALVE
Using a 4 mm hexagon wrench, remove the 2 hexagon bolts.
| *1 | Bolt For The Suction Tube Sub-assembly |
Temporarily install the bolt for the suction hose sub-assembly halfway to the cooler expansion valve.
Hold the bolt and pull it to remove the cooler expansion valve as shown in the illustration.
| *1 | Evaporator Pipe |
Remove the 2 O-rings from the evaporator pipe.