HYBRID BATTERY SYSTEM, Diagnostic DTC:P0A9A-123

DTC Code DTC Name
P0A9A-123 Hybrid Battery Pack Cooling Fan 2 Control Circuit High

DESCRIPTION

Refer to the description for DTC P0A84-123.

Click here

DTC No.

Detection Item

DTC Detection Condition

Trouble Area

MIL

Warning Indicate

P0A9A-123

Hybrid Battery Pack Cooling Fan 2 Control Circuit High

Both of the following conditions are met:

(1 trip detection logic)

  • The speed calculated based on the battery cooling blower assembly LH output frequency (FP1) is not within the target control speed range.

  • The battery cooling blower assembly LH speed is excessively high when a speed below a certain level is requested.

  • Battery voltage sensor

  • Battery cooling blower assembly LH

Does not come on

Master Warning Light:

Comes on

Table 1. Related Data List

DTC No.

Data List

P0A9A-123

  • Cooling Fan 1

  • Cooling Fan Mode2

  • Cooling Fan Frequency2

The following items can be helpful when performing repairs:

  • Data List

  • Temp of Batt TB1 to 6

  • +B

Tip:
  • "Cooling Fan Frequency2" is detected when the battery cooling blower assembly LH is operating and its value changes in proportion to the battery cooling blower assembly LH speed.

  • If the battery cooling blower assembly LH speed is excessively high, this DTC is stored.

WIRING DIAGRAM

Refer to the wiring diagram for DTC P0A84-123.

Click here

CAUTION / NOTICE / HINT

CAUTION:
  • Before inspecting the high-voltage system, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

  • After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

    Click here

    Tip:

    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

Note:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click hereClick hereClick hereClick here

Tip:
  • After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.

    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: Powertrain / Hybrid Control / Active Test / Driving the Battery Cooling Fan.

    4. Select fan mode 6 and operate the battery cooling blower assembly LH.

  • Operation of the battery cooling blower assembly LH can be confirmed by checking if air is sucked into the air intake port of the intake duct.

PROCEDURE

  1. CHECK DTC OUTPUT (HYBRID CONTROL)

    Click hereClick here

    Result

    Result

    Proceed to

    P0AFC-123 is not output.

    A

    P0AFC-123 is also output.

    B

    B

    GO TO DTC CHART (P0AFC-123)

    A
  2. CHECK BATTERY VOLTAGE SENSOR (FREQUENCY)

    Click here

    Result

    Proceed to

    OK

    NG

    OK

    REPLACE BATTERY COOLING BLOWER ASSEMBLY LH

    NG

    REPLACE BATTERY VOLTAGE SENSOR