PROCEDURE
INSTALL PURGE VALVE (PURGE VSV)
| *A | for LHD |
| *B | for RHD |
| *a | 90° |
| *b | 120° |
| *c | Front |
| *d | Paint Mark |
Type A:
Install the purge valve (purge VSV) to the wire harness clamp bracket with the bolt.
Connect the No. 2 fuel vapor feed hose to the purge valve (purge VSV) and slide the clip to secure it.
Tech Tips
Engage the clip within the area shown in the illustration.
Connect the No. 2 fuel vapor feed hose to the purge valve (purge VSV).
Connect the purge valve (purge VSV) connector.
| *A | for LHD |
| *B | for RHD |
| *a | 90° |
| *b | 120° |
| *c | Front |
| *d | Paint Mark |
Type B:
Install the purge valve (purge VSV) to the wire harness clamp bracket with the bolt.
Connect the No. 2 fuel vapor feed hose to the purge valve (purge VSV) and slide the clip to secure it.
Tech Tips
Engage the clip within the area shown in the illustration.
Connect the No. 2 fuel vapor feed hose to the purge valve (purge VSV).
Connect the purge valve (purge VSV) connector.