LIGHTING SYSTEM Footwell Light Circuit

DESCRIPTION

The main body ECU (multiplex network body ECU) controls the interior illumination light assembly (footwell light).

WIRING DIAGRAM

B006EPME01

CAUTION / NOTICE / HINT

Note


  • w/o Stop and Start System:

    Inspect the fuses for circuits related to this system before performing the following procedure.

  • Before replacing the main body ECU (multiplex network body ECU), refer to Service Bulletin.

PROCEDURE


  1. PERFORM ACTIVE TEST USING GTS


    1. Perform the Active Test according to the display on the GTS.

      Click here


      Body Electrical > Main Body > Active Test
      Tester Display Measurement Item Control Range Diagnostic Note
      Fr Foot Light Interior illumination light assembly (footwell light) OFF or ON -

      Body Electrical > Main Body > Active Test
      Tester Display
      Fr Foot Light
      OK
      Interior illumination light assembly (footwell light) turns on or off.
      Result
      Proceed to
      OK
      NG

    OK
    NG
  2. CHECK HARNESS AND CONNECTOR (NO. 1 INTERIOR ILLUMINATION LIGHT ASSEMBLY - BATTERY)


    1. Disconnect the G18 No. 1 interior illumination light assembly (footwell light) connector.

    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      w/ Stop and Start System
      Tester Connection Condition Specified Condition
      G18-2 (B) - Body ground Always 10.5 to 16 V
      w/o Stop and Start System
      Tester Connection Condition Specified Condition
      G18-2 (B) - Body ground Always 11 to 14 V
      Result
      Proceed to
      OK
      NG

    NG
    OK
  3. CHECK INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY


    1. Remove the instrument panel junction block assembly.

      Click here

      B006GFOC01
      *a

      Component without harness connected

      (Instrument Panel Junction Block Assembly)

      - -
    2. Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.

      Click here

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      5A-36 - A-26 (FSPT) Always Below 1 Ω
      Result
      Proceed to
      OK
      NG

    OK
    NG