AIR CONDITIONING SYSTEM DATA LIST / ACTIVE TEST
DATA LIST
Tip:Using the intelligent tester to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
Note:In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
Connect the intelligent tester to the DLC3.
Turn the engine switch on (IG).
Turn the intelligent tester on.
Enter the following menus:
Body / Air Conditioner / Data List.
Powertrain / Engine and ECT / Data List.
According to the display on the intelligent tester, read the Data List.
Body Electrical > Air Conditioner > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Room Temperature Sensor
Cooler thermistor (room temperature sensor)
Min.: -6.5°C (20.3°F)
Max.: 57.25°C (135.05°F)
Actual room temperature for front seat displayed
Open in the circuit: -6.5°C (20.3°F).
Short in the circuit: 57.25°C (135.05°F).
Ambient Temp Sensor
Cooler thermistor (ambient temperature sensor)
Min.: -23.3°C (-9.94°F)
Max.: 65.95°C (150.71°F)
Actual ambient temperature displayed
Open in the circuit: -23.3°C (-9.94°F).
Short in the circuit: 65.95°C (150.71°F).
Adjusted Ambient Temp
Adjusted ambient temperature
Min.: -30.8°C (-23.44°F)
Max.: 50.8°C (123.44°F)
Adjusted ambient temperature displayed
-
Evaporator Fin Thermistor
No. 1 cooler thermistor
Min.: -29.7°C (-21.46°F)
Max.: 59.55°C (139.19°F)
Actual evaporator temperature displayed
Open in the circuit: -29.7°C (-21.46°F).
Short in the circuit: 59.55°C (139.19°F).
Evaporator Target Temp
Target evaporator temperature
Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F)
Target evaporator temperature displayed
-
Solar Sensor (D Side)
Automatic light control sensor (solar sensor)
Min.: 0, Max.: 255
Driver side solar sensor voltage increases as brightness increases
Open in the circuit: 0.
Short in the circuit: 255.
Solar Sensor (P Side)
Automatic light control sensor (solar sensor)
Min.: 0, Max.: 255
Passenger side solar sensor voltage increases as brightness increases
Open in the circuit: 0.
Short in the circuit: 255.
Engine Coolant Temp
Engine coolant temperature
Min.: 1.3°C (34.34°F)
Max.: 90.55°C (194.99°F)
Actual engine coolant temperature displayed
-
Set Temperature (D Side)
Driver side set temperature
MAX COLD, 18.0°C (64.4°F) to 32.0°C (89.6°F) or MAX HOT
Driver side set temperature displayed
18 to 32°C (0.5°C increments)
(64.4 to 89.6 °F [0.9°F increments])
Set Temperature (P Side)
Passenger side set temperature
MAX COLD, 18.0°C (64.4°F) to 32.0°C (89.6°F) or MAX HOT
Passenger side set temperature displayed
18 to 32°C (0.5°C increments)
(64.4 to 89.6 °F [0.9°F increments])
Blower Motor Speed Level
Blower with fan motor sub-assembly speed level
Min.: 0, Max.: 31
Increases in range from 0 to 31 as blower with fan motor sub-assembly speed increases
-
Emission Gas Nox Sensor
Smog ventilation sensor (NOx)
Min.: 0, Max.: 255
Smog ventilation sensor (NOx) value increases as gas amount increases
-
Emission Gas Sensor
Smog ventilation sensor (HC, CO)
Min.: 0, Max.: 255
Smog ventilation sensor (HC, CO) value increases as gas amount increases
-
Regulator Pressure Sensor
Air conditioner pressure sensor
Min.: -0.4566 MPa
Max.: 3.2943 MPa
Actual refrigerant pressure displayed
-
Room Temp Sensor (Rear)
Cooler thermistor (rear room temperature sensor)
Min.: -6.5°C (20.3°F)
Max.: 57.25°C (135.05°F)
Actual rear cabin temperature displayed
-
Evap Temp Sensor (Rear)
Rear evaporator temperature sensor
Min.: -29.7 C (-21.46 F)
Max.: 59.25 C (138.65 F)
Actual rear evaporator temperature displayed
-
Set Temperature (Rear)
Rear set temperature
MAX COLD, 18.0°C (64.4°F) to 32.0°C (89.6°F) or MAX HOT
Actual rear set temperature displayed
18 to 32°C (0.5°C increments)(64.4 to 89.6 °F [0.9°F increments])
Blower Motor Level (Rear)
Rear blower with fan motor sub-assembly speed level
Min.: 0, Max.: 31
Increases in range from 0 to 31 as rear blower with fan motor sub-assembly speed increases
-
Air Outlet Servo Pulse (R)
Rear No. 2 cooling unit damper servo sub-assembly (rear mode damper servo) target pulse
Min.: 0, Max.: 255
83 (pulse): FACE
41 (pulse): B/L
7 (pulse): FOOT
-
Air Outlet Servo Actual Pls(R)
Rear No. 2 cooling unit damper servo sub-assembly (rear mode damper servo) actual pulse
Min.: 0, Max.: 255
83 (pulse): FACE
41 (pulse): B/L
7 (pulse): FOOT
-
Air Mix Servo Targ Pulse(R)
Rear No. 1 cooling unit damper servo sub-assembly (rear air mix damper servo) target pulse
Min.: 0, Max.: 255
9 (pulse): MAX COOL
54 (pulse): MAX HOT
-
Air Mix Servo Actual Pulse(R)
Rear No. 1 cooling unit damper servo sub-assembly (rear air mix damper servo) target pulse
Min.: 0, Max.: 255
9 (pulse): MAX COOL
54 (pulse): MAX HOT
-
Air Mix Servo Targ Pulse(D)
No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix damper servo) target pulse
Min.: 0, Max.: 255
107 (pulse): MAX COOL
26 (pulse): MAX HOT
-
Air Mix Servo Actual Pulse(D)
No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix damper servo) actual pulse
Min.: 0, Max.: 255
107 (pulse): MAX COOL
26 (pulse): MAX HOT
-
Air Mix Servo Targ Pulse(P)
No. 2 air conditioning radiator damper servo sub-assembly (front passenger side air mix damper servo) target pulse
Min.: 0, Max.: 255
112 or 127 (pulse): MAX COOL
21 or 31 (pulse): MAX HOT
-
Air Mix Servo Actual Pulse(P)
No. 2 air conditioning radiator damper servo sub-assembly (front passenger side air mix damper servo) actual pulse
Min.: 0, Max.: 255
112 or 127 (pulse): MAX COOL
21 or 31 (pulse): MAX HOT
-
Air Outlet Servo Pulse (D)
No. 1 air conditioning radiator damper servo sub-assembly (mode damper servo) actual pulse
Min.: 0, Max.: 255
15 (pulse): FACE 1
23 (pulse): FACE 2
41 (pulse): B/L
65 or 73 (pulse): FOOT
83 or 95 (pulse): F/D
113 (pulse): DEF
-
Air Outlet Servo Actu Pulse(D)
No. 1 air conditioning radiator damper servo sub-assembly (mode damper servo) actual pulse
Min.: 0, Max.: 255
15 (pulse): FACE 1
23 (pulse): FACE 2
41 (pulse): B/L
65 or 73 (pulse): FOOT
83 or 95 (pulse): F/D
113 (pulse): DEF
-
Air Inlet Damper Targ Pulse
Recirculation damper servo sub-assembly target pulse
Min.: 0, Max.: 255
7 (pulse): Recirculation
28 (pulse): Fresh
-
Air Inlet Damper Actual Pulse
Recirculation damper servo sub-assembly actual pulse
Min.: 0, Max.: 255
7 (pulse): Recirculation
28 (pulse): Fresh
-
Electric Heater Count
Number of electric heaters operating
Min.: 0, Max.: 3
-
w/ PTC Heater
Electric Heater Active Level
Number of electric heaters operating
Min.: 0, Max.: 3
-
w/ PTC Heater
Shift Set Temperature
Set temperature shift
2C incr, 1C incr, Normal, 1C decr or 2C decr
Customized setting displayed
-
Air Inlet Mode
Air inlet mode
Auto or Manual
Customized setting displayed
-
Compressor Mode
Compressor mode
Auto or Manual
Customized setting displayed
-
Emission Gas Sensor Shift
Emission Gas Sensor shift
More, Mu Less, Less, Li Less, Li More, Mu More or Normal
Customized setting displayed
-
Add Foot Air in FACE Mode
Add foot air in face mode
ON or OFF
Customized setting displayed
-
Button Press Buzzer
Button press buzzer
ON or OFF
Customized setting displayed
-
Foot/DEF Auto Mode
Foot/Def auto mode
ON or OFF
Customized setting displayed
-
Foot/DEF Auto Blow Up
Foot/Def auto blower level function
ON or OFF
Customized setting displayed
-
Pls Servo Test Sts
Pulse servo motor test status
Wait, Move, Comp, Erro or Stop
Wait: Servo motor test not yet performed
Move: Servo motor now testing
Comp: Servo motor test completed normally
Error: Servo motor test completed abnormally
Stop: Servo motor test interrupted
-
Outside Air Mode Auto Switch Function
Switch ON/OFF the function to switch the suction opening to the outside air mode automatically when the ignition switch is turned off
ON or OFF
Customized setting displayed
-
Number of Trouble Codes
Number of trouble codes
Min.: 0, Max.: 255
Number of DTCs stored
-
Powertrain > Engine and ECT > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
A/C Signal
A/C signal
ON or OFF
ON: A/C switch on
OFF: A/C switch off
-
ACTIVE TEST
Tip:Using the intelligent tester to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
Connect the intelligent tester to the DLC3.
Turn the engine switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Body / Air Conditioner / Active Test.
According to the display on the intelligent tester, perform the Active Test.
Body Electrical > Air Conditioner > Active Test
Tester Display
Measurement Item
Control Range
Diagnostic Note
Blower Motor
Blower with fan motor sub-assembly
Min.: 0, Max.: 31
-
Magnetic Clutch Relay
Magnet clutch relay operation
ON or OFF
-
Defogger Relay (Rear)
Rear window defogger relay operation
ON or OFF
-
Electrical Fan
Motor cooling fan operation
ON or OFF
-
Heater Active Level
Heater level
Min.: 0, Max.: 3
w/ PTC Heater
Air Mix Servo Targ Pulse(D)
No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix damper servo) target pulse
Min.: 0, Max.: 255
-
Air Mix Servo Targ Pulse(P)
No. 2 air conditioning radiator damper servo sub-assembly (front passenger side air mix damper servo) pulse
Min.: 0, Max.: 255
-
Air Outlet Servo Pulse (D)
No. 1 air conditioning radiator damper servo sub-assembly (mode damper servo) pulse
Min.: 0, Max.: 255
-
Air Inlet Damper Targ Pulse
Recirculation damper servo sub-assembly target pulse
Min.: 0, Max.: 255
-
Rear Blower Motor
Rear blower with fan motor sub-assembly
Min.: 0, Max.: 31
-
Rear Air Mix Servo Targ Pulse
Rear No. 1 cooling unit damper servo sub-assembly (rear air mix damper servo) target pulse
Min.: 0, Max.: 255
-
Rear A/C Mag Valve
Rear magnetic valve operation
ON or OFF
-
A/O Servo Pulse(Rr D)
Rear No. 2 cooling unit damper servo sub-assembly (rear mode damper servo) pulse
Min.: 0, Max.: 255
-