AIR CONDITIONING SYSTEM, Diagnostic DTC:B1413/13
| DTC Code | DTC Name |
|---|---|
| B1413/13 | Evaporator Temperature Sensor Circuit |
DESCRIPTION
The No. 1 cooler thermistor is installed on the evaporator in the air conditioning unit to detect the temperature of the cooled air that has passed through the evaporator and control the air conditioning. It sends appropriate signals to the air conditioning amplifier assembly. The resistance of the No. 1 cooler thermistor changes in accordance with the temperature of the cooled air that has passed through the evaporator. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies voltage (5 V) to the No. 1 cooler thermistor and reads voltage changes as the resistance of the No. 1 cooler thermistor changes. This sensor is used for frost prevention.
DTC No. |
Detection Item |
DTC Detection Condition |
Trouble Area |
Memory |
Note |
|---|---|---|---|---|---|
B1413/13 |
Evaporator Temperature Sensor Circuit |
An open or short in the No. 1 cooler thermistor circuit. |
|
Stored (4 seconds or more) |
- |
WIRING DIAGRAM
PROCEDURE
READ VALUE USING INTELLIGENT TESTER (NO. 1 COOLER THERMISTOR)
Use the Data List to check if the No. 1 cooler thermistor is functioning properly
Body Electrical > Air Conditioner > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Evaporator Fin Thermistor
No. 1 cooler thermistor
Min.: -29.7°C (-21.46°F)
Max.: 59.55°C (139.19°F)
Actual evaporator temperature displayed
Open in the circuit: -29.7°C (-21.46°F).
Short in the circuit: 59.55°C (139.19°F).
Body Electrical > Air Conditioner > Data List
Tester Display
Evaporator Fin Thermistor
OK
The display is as specified in the normal condition column.
Result
Result
Proceed to
OK (When troubleshooting according to problem symptoms table)
A
OK (When troubleshooting according to the DTC)
B
NG
C
INSPECT NO. 1 COOLER THERMISTOR
-
*a
Sensing Portion
*b
Resistance
*c
Allowable Range
*d
Temperature
Remove the No. 1 cooler thermistor
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
1 - 2
-10°C (14°F)
7.30 to 9.10 kΩ
-5°C (23°F)
5.65 to 6.95 kΩ
0°C (32°F)
4.40 to 5.35 kΩ
5°C (41°F)
3.40 to 4.15 kΩ
10°C (50°F)
2.70 to 3.25 kΩ
15°C (59°F)
2.14 to 2.58 kΩ
20°C (68°F)
1.71 to 2.05 kΩ
25°C (77°F)
1.38 to 1.64 kΩ
30°C (86°F)
1.11 to 1.32 kΩ
Note:Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
When measuring, the sensor temperature must be the same as the ambient temperature.
Tip:As the temperature increases, the resistance decreases (refer to the graph).
Result
Result
OK
NG
-
INSPECT AIR CONDITIONING HARNESS ASSEMBLY
-
*a
Front view of wire harness connector
(to No. 1 Cooler Thermistor)
*b
Front view of wire harness connector
(to Air Conditioning Amplifier Assembly)
Remove the air conditioning harness assembly
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
z1-6 (TEA) - 2
Always
Below 1 Ω
z1-5 (SGA) - 1
Always
Below 1 Ω
z1-6 (TEA) - Body ground
Always
10 kΩ or higher
z1-5 (SGA) - Body ground
Always
10 kΩ or higher
Result
Result
OK
NG
-