AIR CONDITIONING SYSTEM Back-up Power Source Circuit

DESCRIPTION

The back-up power source circuit for the air conditioning amplifier assembly is shown below. Power is supplied even when the power switch is turned off. The power is used for DTC memory etc.

WIRING DIAGRAM

A005D04E02
*1 from Auxiliary Battery
*2 Air Conditioning Amplifier Assembly

CAUTION / NOTICE / HINT

Note

Inspect the fuses for circuits related to this system before performing the following inspection procedure.

PROCEDURE


  1. CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - POWER SOURCE)


    1. Disconnect the L17 air conditioning amplifier assembly connector.

    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      L17-21 (B) - Body ground Power switch off 11 to 14 V

    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - BODY GROUND)


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      L17-14 (GND) - Body ground Always Below 1 Ω

    OK
    NG