DESCRIPTION
If cool air blows from the registers regardless of the temperature setting of the air conditioning system, the following factors may be the cause.
| Symptom | Factor |
|---|---|
|
|
*1: w/ Quick Heater
*2: for A25A-FKS
PROCEDURE
CONFIRM MODEL
| Result | ||||||
|---|---|---|---|---|---|---|
|
| A |
|
GO TO STEP 3 Click here |
| B |
|
CHECK FOR DTC
Check for DTCs.
| OK |
|---|
| SFI system DTCs are not output. |
| Result | |||
|---|---|---|---|
|
| NG |
|
GO TO SFI SYSTEM for A25A-FKS (w/ Canister Pump Module): Click here |
| OK |
|
READ VALUE USING GTS
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Powertrain / Engine / Data List.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Coolant Temperature | Engine coolant temperature | Min.: -40°C (-40°F), Max.: 140°C (284°F) | 75 to 100°C (167 to 212°F): After warming up | This is the engine coolant temperature. Tech Tips
|
| Tester Display |
|---|
| Coolant Temperature |
| OK |
|---|
| After warming up the engine, the temperature value displayed is within the range specified in the normal condition column. |
| Result | |||
|---|---|---|---|
|
| NG |
|
GO TO COOLING SYSTEM for 2AR-FE: Click here |
| OK |
|
PERFORM ACTIVE TEST USING GTS
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Active Test.
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Air Mix Servo Targ Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) pulse | Min.: 128 Max.: 383 |
for LHD:
for RHD: |
| Air Mix Servo Targ Pulse(P) | No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) pulse | Min.: 128 Max.: 383 |
for LHD:
for RHD: |
| Rear Air Mix Servo Targ Pulse | No. 3 air conditioning radiator damper servo sub-assembly pulse | Min.: 128 Max.: 383 |
|
*: for 3 Zone Type
| Tester Display |
|---|
| Air Mix Servo Targ Pulse(D) |
| Tester Display |
|---|
| Air Mix Servo Targ Pulse(P) |
| Tester Display |
|---|
| Rear Air Mix Servo Targ Pulse |
| OK |
|---|
| Each damper servo motor operates. |
| Result | |||
|---|---|---|---|
|
| NG |
|
GO TO DTC TROUBLESHOOTING PROCEDURE FOR MALFUNCTIONING DAMPER SERVO MOTOR Click here |
| OK |
|
CONFIRM MODEL
| Result | ||||||
|---|---|---|---|---|---|---|
|
| B |
|
REPLACE HEATER RADIATOR UNIT SUB-ASSEMBLY Click here |
| A |
|
PERFORM ACTIVE TEST USING GTS
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Active Test / Heater Active Level / Data List / Electric Heater Active Level.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Heater Active Level | Quick heater assembly | Min.: 0 Max.: 2 |
- |
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Electric Heater Active Level | Actual electric heater operation level | Min.: 0 Max.: 2 |
Actual operation level of electric heater displayed | PTC heater circuit system malfunction |
| Active Test Display |
|---|
| Heater Active Level |
| Data List Display |
|---|
| Electric Heater Active Level |
Check that the value of the Data List item Electric Heater Active Level changes in accordance with the set value of the Active Test item Heater Active Level.
| OK | ||||
|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| OK |
|
REPLACE HEATER RADIATOR UNIT SUB-ASSEMBLY Click here |
| NG |
|
GO TO PTC HEATER CIRCUIT Click here |