HEATED OXYGEN SENSOR INSPECTION

PROCEDURE


  1. INSPECT HEATED OXYGEN SENSOR

    A0059Z3E02
    Text in Illustration
    *a

    Component without harness connected

    (Heated Oxygen Sensor)


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      D9-1 (HT1B) - D9-2 (+B) 20°C (68°F) 11 to 16 Ω
      D9-1 (HT1B) - D9-4 (E2) - 10 kΩ or higher

      If the result is not as specified, replace the heated oxygen sensor.