PROCEDURE
REMOVE DIFFERENTIAL PRESSURE SENSOR (for Bank 1)
Disconnect the differential pressure sensor connector.
Slide the clip and disconnect the No. 2 vacuum transmitting hose assembly from the differential pressure sensor.
Remove the nut and differential pressure sensor from the sensor bracket.
REMOVE DIFFERENTIAL PRESSURE SENSOR (for Bank 2)
Disconnect the differential pressure sensor connector.
Slide the clip and disconnect the No. 1 vacuum transmitting hose assembly from the differential pressure sensor.
Remove the nut and differential pressure sensor from the sensor bracket.