PROCEDURE
RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM
for HFC-134a (R134a):
for HFO-1234yf (R1234yf):
REMOVE AIR CLEANER ASSEMBLY
REMOVE GENERATOR COVER
REMOVE BELT GENERATOR COVER
REMOVE FAN AND GENERATOR V BELT
DISCONNECT SUCTION HOSE SUB-ASSEMBLY
Remove the bolt and disconnect the suction hose sub-assembly from the compressor with magnet clutch.
Remove the O-ring from the suction hose sub-assembly.
Note
Seal the openings of the disconnected parts using vinyl tape to prevent entry of moisture and foreign matter.
DISCONNECT NO. 1 COOLER REFRIGERANT DISCHARGE HOSE
Remove the bolt and disconnect the No. 1 cooler refrigerant discharge hose from the compressor with magnet clutch.
Remove the O-ring from the No. 1 cooler refrigerant discharge hose.
Note
Seal the openings of the disconnected parts using vinyl tape to prevent entry of moisture and foreign matter.
REMOVE COMPRESSOR WITH MAGNET CLUTCH
Disconnect the connector.
Remove the 3 bolts and the compressor with magnet clutch.