2KD-FTV FUEL SERVICE DATA
FUEL INJECTOR (for DPF)
| Tester Connection |
Condition |
Specified Condition |
| 1 - 2 |
20°C (68°F) |
20 MΩ or more |
FUEL INJECTOR (w/ EGR Cooler)
| Tester Connection |
Condition |
Specified Condition |
| 1 - 2 |
20°C (68°F) |
0.42 to 0.52 Ω |
FUEL INJECTOR (w/o EGR Cooler)
| Tester Connection |
Condition |
Specified Condition |
| 1 - 2 |
20°C (68°F) |
0.42 to 0.52 Ω |
FUEL SUPPLY PUMP (for DPF)
| Item |
Tester Connection |
Condition |
Specified Condition |
| Suction control valve |
1 - 2 |
20°C (68°F) |
1.9 to 2.3 Ω |
| Fuel temperature sensor |
1 - 2 |
20°C (68°F) |
2.32 to 2.59 kΩ |
FUEL SUPPLY PUMP (for EGR Cooler)
| Item |
Tester Connection |
Condition |
Specified Condition |
| Suction control valve |
1 - 2 |
20°C (68°F) |
1.9 to 2.3 Ω |
FUEL SUPPLY PUMP (w/o EGR Cooler)
| Item |
Tester Connection |
Condition |
Specified Condition |
| Suction control valve |
1 - 2 |
20°C (68°F) |
1.9 to 2.3 Ω |
COMMON RAIL (for DPF)
| Item |
Tester Connection |
Condition |
Specified Condition |
| Fuel pressure sensor |
2 - 3 |
25°C (77°F) |
16.4 kΩ or less |
| 5 - 4 |
25°C (77°F) |
16.4 kΩ or less |
| 1 - 2 |
25°C (77°F) |
3 kΩ or less |
| 6 - 5 |
25°C (77°F) |
3 kΩ or less |
| Pressure discharge valve |
1 - 2 |
20°C (68°F) |
0.96 to 1.16 Ω |
COMMON RAIL (w/ EGR Cooler)
| Item |
Tester Connection |
Condition |
Specified Condition |
| Fuel pressure sensor |
2 - 3 |
25°C (77°F) |
16.4 kΩ or less |
| 5 - 4 |
25°C (77°F) |
16.4 kΩ or less |
| 1 - 2 |
25°C (77°F) |
3 kΩ or less |
| 6 - 5 |
25°C (77°F) |
3 kΩ or less |
| Pressure discharge valve |
1 - 2 |
20°C (68°F) |
0.85 to 1.05 Ω |
COMMON RAIL (w/o EGR Cooler)
| Item |
Tester Connection |
Condition |
Specified Condition |
| Fuel pressure sensor |
2 - 3 |
25°C (77°F) |
16.4 kΩ or less |
| 5 - 4 |
25°C (77°F) |
16.4 kΩ or less |
| 1 - 2 |
25°C (77°F) |
3 kΩ or less |
| 6 - 5 |
25°C (77°F) |
3 kΩ or less |
| Pressure discharge valve |
1 - 2 |
20°C (68°F) |
0.85 to 1.05 Ω |
FUEL FILTER
| Item |
Tester Connection |
Condition |
Specified Condition |
| Level warning switch |
1 - 2 |
ON |
Below 1 Ω |
| 1 - 2 |
OFF |
10 kΩ or higher |
| Clogging switch |
1 - 2 |
20°C (68°F) |
Below 1 Ω |