FRONT EVAPORATOR TEMPERATURE SENSOR INSPECTION
PROCEDURE
INSPECT NO. 1 COOLER THERMISTOR
Measure the resistance according to the value(s) in the table below.
*a
Component without harness connected
(No. 1 Cooler Thermistor)
*b
Sensing Portion
*c
Resistance (kΩ)
*d
Allowable Range
*e
Temperature (°C (°F))
-
-
Standard Resistance
Tester Connection
Condition
Specified Condition
1 - 2
-10°C (14°F)
7.30 to 9.10 kΩ
1 - 2
-5°C (23°F)
5.65 to 6.95 kΩ
1 - 2
0°C (32°F)
4.40 to 5.35 kΩ
1 - 2
5°C (41°F)
3.40 to 4.15 kΩ
1 - 2
10°C (50°F)
2.70 to 3.25 kΩ
1 - 2
15°C (59°F)
2.14 to 2.58 kΩ
1 - 2
20°C (68°F)
1.71 to 2.05 kΩ
1 - 2
25°C (77°F)
1.38 to 1.64 kΩ
1 - 2
30°C (86°F)
1.11 to 1.32 kΩ
Note:Hold the sensor only by its connector. Touching the sensing portion may change the resistance value.
When measuring, the sensor temperature must be the same as the ambient temperature.
Tip:As the temperature increases, the resistance decreases (See the graph).
If the result is not as specified, replace the No. 1 cooler thermistor.