2GD-FTV EMISSION CONTROL SERVICE DATA

NO. 1 VACUUM SWITCHING VALVE ASSEMBLY
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 33 to 39 Ω

1 - Body ground

2 - Body ground

20°C (68°F) 1 MΩ or higher
EXHAUST GAS TEMPERATURE SENSOR
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 89.3 to 159.8 kΩ
EXHAUST GAS TEMPERATURE SENSOR (w/ Urea SCR System)
Tester Connection Condition Specified Condition
1 - 2 50°C (122°F) 7894 to 12187 Ω
1 - 2 650°C (1202°F) 73 to 79 Ω
EXHAUST FUEL ADDITION INJECTOR
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 7.1 to 7.9 Ω
UREA INJECTOR
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 11.6 to 12.4 kΩ
UREA PUMP
Item Tester Connection Condition Specified Condition
Level sensor 14 (LV1) - 6 (ELV1) Float is up 23.37 to 24.47 kΩ
14 (LV1) - 6 (ELV1) Float is down 1.40 to 1.46 kΩ
Tank heater 9 (TH+) - 11 (TH-) 25°C (77°F) 1.39 to 1.54 kΩ
Temperature sensor 1 (TUW) - 2 (ETUW) 20°C (68°F) 2.47 to 2.56 kΩ
1 (TUW) - 2 (ETUW) 30°C (86°F) 1.69 to 1.75 kΩ
Pump motor 7 (PHAA) - 8 (PHAB) 20 to 30 °C (68 to 86°F) 0.35 to 0.43 Ω
7 (PHAA) - 16 (PHAC) 20 to 30 °C (68 to 86°F) 0.35 to 0.43 Ω
8 (PHAB) - 16 (PHAC) 20 to 30 °C (68 to 86°F) 0.35 to 0.43 Ω
7 (PHAA) - 15 (MGND) Always 10 kΩ or higher
8 (PHAB) - 15 (MGND) Always 10 kΩ or higher
16 (PHAC) - 15 (MGND) Always 10 kΩ or higher