COMBUSTION TYPE POWER HEATER SYSTEM, Diagnostic DTC:010 and 011
| DTC Code | DTC Name |
|---|---|
| 010 | Over Voltage Shutoff |
| 011 | Under Voltage Shutoff |
DESCRIPTION
DTC Code |
DTC Detection Condition |
Trouble Area |
|---|---|---|
010 |
Battery voltage is 14 V or higher for 20 seconds or more. |
|
011 |
Battery voltage is 11 V or less for 20 seconds or more. |
WIRING DIAGRAM
CAUTION / NOTICE / HINT
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
Before performing the following procedures, check the battery and generator assembly and confirm that they are operating normally.
PROCEDURE
CHECK HARNESS AND CONNECTOR (HEATER ASSEMBLY - BATTERY AND BODY GROUND)
-
Disconnect the A41 heater connector.
Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection
Condition
Specified Condition
A41-5 (B) - Body ground
Always
11 to 14 V
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
A41-1 (E) - Body ground
Always
Below 1 Ω
Table 1. Text in Illustration *1
Front view of wire harness connector
(to Heater Assembly)
REPAIR OR REPLACE HARNESS OR CONNECTOR
-