VACUUM PUMP(When Using the Engine Support Bridge for AD Series Engine) ON-VEHICLE INSPECTION
PROCEDURE
OPERATION CHECK
Disconnect the vacuum hose from the vacuum pump.
-
*a
Vacuum Gauge
Connect the hose of the vacuum gauge to the vacuum pump.
Start the engine and warm it up for more than 2 minutes.
With the engine idling, check the negative pressure of the vacuum pump.
Standard pressure
More than 87 kPa (650 mmHg, 25.6 in.Hg)
Tip:If the result is not as specified, replace the vacuum pump.
Remove the vacuum gauge from the vacuum pump.
Connect the vacuum hose to the vacuum pump.