GENERATOR(for 130 A Type) INSTALLATION

PROCEDURE

  1. INSTALL GENERATOR ASSEMBLY

    1. Install the generator with the 3 bolts and nut.

      43 N*m

      438 kgf*cm

      32 ft.*lbf

    2. Connect the wire harness bracket to the generator with the bolt.

      24 N*m

      245 kgf*cm

      18 ft.*lbf

    3. Attach the generator wire.

    4. Connect the generator wire with the nut.

      9.8 N*m

      100 kgf*cm

      87 in.*lbf

    5. Install the terminal cap.

    6. Connect the generator connector.

    7. A230309

      Connect the No. 2 return tube bracket with the bolt.

      28 N*m

      286 kgf*cm

      21 ft.*lbf

  2. CONNECT VANE PUMP ASSEMBLY

    1. Connect the vane pump with the 2 bolts.

      43 N*m

      438 kgf*cm

      32 ft.*lbf

    2. Attach the clamp and connect the connector.

  3. INSTALL FRONT FENDER APRON SEAL RH

  4. INSTALL AIR CLEANER CASE SUB-ASSEMBLY

  5. INSTALL AIR CLEANER FILTER ELEMENT SUB-ASSEMBLY

  6. INSTALL AIR CLEANER CAP AND HOSE

  7. INSTALL RADIATOR ASSEMBLY

    1. Install the radiator assembly (Click hereClick here).

  8. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

    Note:

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected (Click hereClick hereClick hereClick here).