GENERATOR(for 130 A Type) INSTALLATION
PROCEDURE
INSTALL GENERATOR ASSEMBLY
Install the generator with the 3 bolts and nut.
43 N*m
438 kgf*cm
32 ft.*lbf
Connect the wire harness bracket to the generator with the bolt.
24 N*m
245 kgf*cm
18 ft.*lbf
Attach the generator wire.
Connect the generator wire with the nut.
9.8 N*m
100 kgf*cm
87 in.*lbf
Install the terminal cap.
Connect the generator connector.
-
Connect the No. 2 return tube bracket with the bolt.
28 N*m
286 kgf*cm
21 ft.*lbf
CONNECT VANE PUMP ASSEMBLY
Connect the vane pump with the 2 bolts.
43 N*m
438 kgf*cm
32 ft.*lbf
Attach the clamp and connect the connector.
INSTALL FRONT FENDER APRON SEAL RH
INSTALL AIR CLEANER CASE SUB-ASSEMBLY
INSTALL AIR CLEANER FILTER ELEMENT SUB-ASSEMBLY
INSTALL AIR CLEANER CAP AND HOSE
INSTALL RADIATOR ASSEMBLY
Install the radiator assembly (Click hereClick here).
CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
Note:When disconnecting the cable, some systems need to be initialized after the cable is reconnected (Click hereClick hereClick hereClick here).