INTEGRATION RELAY INSPECTION

PROCEDURE


  1. INSPECT NO. 1 INTEGRATION RELAY

    A001XE6E04

    1. IG1 NO. 3 RELAY:


      1. A001TSSC02
        *a

        Component without harness connected

        (No. 1 Integration Relay)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        1A-4 - 1A-3 Battery voltage not applied between terminals 1A-2 and 1A-1 10 kΩ or higher

        Battery positive (+) → 1A-2

        Battery negative (-) → 1A-1

        Below 1 Ω

        If the result is not as specified, replace the No. 1 integration relay.

    2. H-LP LH RELAY:


      1. A001TSSC02
        *a

        Component without harness connected

        (No. 1 Integration Relay)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        1A-5 - 1B-1 Battery voltage not applied between terminals 1A-5 and 1B-2 10 kΩ or higher

        Battery positive (+) → 1A-5

        Battery negative (-) → 1B-2

        Below 1 Ω

        If the result is not as specified, replace the No. 1 integration relay.

    3. EFI-MAIN RELAY:


      1. A001TSSC02
        *a

        Component without harness connected

        (No. 1 Integration Relay)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        1B-3 - 1B-4 Battery voltage not applied between terminals 1B-5 and 1B-6 10 kΩ or higher

        Battery positive (+) → 1B-5

        Battery negative (-) → 1B-6

        Below 1 Ω

        If the result is not as specified, replace the No. 1 integration relay.

    4. IG2 NO. 1 RELAY:


      1. A001TSSC02
        *a

        Component without harness connected

        (No. 1 Integration Relay)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        1A-10 - 1A-9 Battery voltage not applied between terminals 1A-7 and 1A-8 10 kΩ or higher

        Battery positive (+) → 1A-7

        Battery negative (-) → 1A-8

        Below 1 Ω

        If the result is not as specified, replace the No. 1 integration relay.

    5. H-LP RH RELAY:


      1. A001TSSC02
        *a

        Component without harness connected

        (No. 1 Integration Relay)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        1B-8 - 1A-12 Battery voltage not applied between terminals 1B-8 and 1A-11 10 kΩ or higher

        Battery positive (+) → 1B-8

        Battery negative (-) → 1A-11

        Below 1 Ω

        If the result is not as specified, replace the No. 1 integration relay.

    6. P-CON RELAY:


      1. A001TSSC02
        *a

        Component without harness connected

        (No. 1 Integration Relay)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        1B-9 - 1B-10 Battery voltage not applied between terminals 1B-11 and 1B-12 10 kΩ or higher

        Battery positive (+) → 1B-11

        Battery negative (-) → 1B-12

        Below 1 Ω

        If the result is not as specified, replace the No. 1 integration relay.