SPIRAL CABLE(for Single Type) INSPECTION
PROCEDURE
INSPECT SPIRAL CABLE SUB-ASSEMBLY
Note:Do not remove the steering sensor from the spiral cable sub-assembly.
As the spiral cable sub-assembly may break, do not rotate the spiral cable sub-assembly more than the specified amount.
Visually check for defects with the spiral cable sub-assembly.
The defects are as follows:
Scratches
Small cracks
Dents
Chips
Cracks or other damage to the connector
OK
No defects are found.
If any of the defects is found, replace the spiral cable sub-assembly with a new one.
Check the spiral cable sub-assembly.
Note:When rotating the spiral cable sub-assembly, make sure to push on the interlock indicated in the illustration to release the interlock mechanism.
*A
w/ Steering Heater
-
-
*a
Component without harness connected
(spiral cable sub-assembly)
-
-

Interlock
-
-
Set the spiral cable sub-assembly to the center position.
Measure the resistance between each terminal of the spiral cable sub-assembly according to the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
G9-1 (D+) - z2-2
Always
Below 1 Ω
G9-2 (D-) - z2-1
G8-1 (CCS) - z4-3
3 Ω or less
G8-2 (ECC) - z1-7
G8-2 (ECC) - z4-4
G8-3 (EAU) - z1-8
G8-4 (ASL) - z1-9
G8-5 (AU2) - z1-10
G8-6 (AU1) - z1-11
G8-7 (SDN) - z1-12
G8-9 (IL+2) - z1-5
G8-10 (+DP) - z1-2
G8-11 (-DP) - z1-3
G8-12 (DIST) - z1-4
G8-13 (HO) - z1-1
G8-14 (SUP) - z1-6
G175-2 (EHT) - Z5-3
Below 0.1 Ω
G175-4 (BHT) - Z5-4
After setting the spiral cable sub-assembly to the center position, rotate the spiral cable sub-assembly 2.5 times clockwise, and measure the resistance as shown in the table below. Then rotate the spiral cable sub-assembly 5 times counterclockwise, and measure the resistance as shown in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
G9-1 (D+) - z2-2
Always
Below 1 Ω
G9-2 (D-) - z2-1
G8-1 (CCS) - z4-3
3 Ω or less
G8-2 (ECC) - z1-7
G8-2 (ECC) - z4-4
G8-3 (EAU) - z1-8
G8-4 (ASL) - z1-9
G8-5 (AU2) - z1-10
G8-6 (AU1) - z1-11
G8-7 (SDN) - z1-12
G8-9 (IL+2) - z1-5
G8-10 (+DP) - z1-2
G8-11 (-DP) - z1-3
G8-12 (DIST) - z1-4
G8-13 (HO) - z1-1
G8-14 (SUP) - z1-6
G175-2 (EHT) - Z5-3
Below 0.1 Ω
G175-4 (BHT) - Z5-4
After setting the spiral cable sub-assembly to the center position, rotate the spiral cable sub-assembly 2.5 times clockwise. Then while rotating the spiral cable sub-assembly 5 times counterclockwise, measure the resistance as shown in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
G9-1 (D+) - z2-2
Always
Below 1 Ω
G9-2 (D-) - z2-1
G8-1 (CCS) - z4-3
3 Ω or less
G8-2 (ECC) - z1-7
G8-2 (ECC) - z4-4
G8-3 (EAU) - z1-8
G8-4 (ASL) - z1-9
G8-5 (AU2) - z1-10
G8-6 (AU1) - z1-11
G8-7 (SDN) - z1-12
G8-9 (IL+2) - z1-5
G8-10 (+DP) - z1-2
G8-11 (-DP) - z1-3
G8-12 (DIST) - z1-4
G8-13 (HO) - z1-1
G8-14 (SUP) - z1-6
G175-2 (EHT) - Z5-3
Below 0.1 Ω
G175-4 (BHT) - Z5-4
If the result is not as specified, replace the spiral cable sub-assembly.