INSPECT DECELERATION SENSOR
Connect 3 dry cell batteries of 1.5 V in series (approximately 4.5 V total).
Connect the batteries' positive (+) lead to terminal 3 (VGS) and the negative (-) lead to terminal 2 (GGND).
Note
Do not apply 6 V or higher to terminals 3 (VGS) and 2 (GGND).
Connect the voltmeter's positive (+) lead to the negative (-) lead of the batteries, and the negative (-) lead to terminal 1 (GL1).
Check the output voltage of terminal 1 (GL1) when the sensor is tilted forward and rearward.
| Standard Voltage | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the deceleration sensor.
Tech Tips
If voltage drops, the sensor should be replaced with a new one.
When replacing the sensor, it should not be placed upside down.