2KD-FTV INTAKE SERVICE DATA

for DPF
Manifold absolute pressure sensor Condition Tester Connection Specified Condition
ECM output voltage 3 VC (+) - 1 E2 (-) 4.75 to 5.25 V
Applied vacuum - -
13.3 kPa (100 mmHg, 3.94 in.Hg) E27-5 (PIM +) - E27-14 (E2-) 0.8 to 1.4 V
26.6 kPa (199 mmHg, 7.85 in.Hg) 0.5 to 1.0 V
40 kPa (300 mmHg, 11.81 in.Hg) 0.3 to 0.9 V
Applied pressure - -

19.6 kPa (0.20 kgf/cm2, 2.84 psi)

E27-5 (PIM +) - E27-14 (E2-) 1.0 to 1.7 V

39.2 kPa (0.40 kgf/cm2, 5.69 psi)

1.3 to 1.9 V

58.8 kPa (0.60 kgf/cm2, 8.53 psi)

1.5 to 2.2 V

78.5 kPa (0.80 kgf/cm2, 11.4 psi)

1.8 to 2.4 V

98.0 kPa (1.00 kgf/cm2, 14.2 psi)

2.1 to 2.7 V
Turbocharger boost pressure Standard pressure

5 to 20 kPa (0.05 to 0.2 kgf/cm2, 0.7 to 2.9 psi)

Turbocharger Axial play of turbine shaft Maximum axial play 0.11 mm (0.0043 in.)
w/ EGR cooler
Manifold absolute pressure sensor Condition Tester connection Specified Condition
ECM output voltage 3 (VC (+)) - 1 (E2 (-)) 4.75 to 5.25 V
Applied vacuum - -
13.3 kPa (100 mmHg, 3.94 in.Hg) E7-28 (PIM (+)) - E8-28 (E2 (-)) 0 to 0.3 V
26.6 kPa (199 mmHg, 7.85 in.Hg) 0.1 to 0.4 V
40 kPa (300 mmHg, 11.81 in.Hg) 0.2 to 0.6 V
Applied pressure - -

19. 6 kPa (0.20 kgf/cm2, 2.84 psi)

E7-28 (PIM (+)) - E8-28 (E2( -)) 0.05 to 0.3 V

39.2 kPa (0.40 kgf/cm2, 5.69 psi)

0.25 to 0.55 V

58.8 kPa (0.60 kgf/cm2, 8.53 psi)

0.45 to 0.75 V

78.5 kPa (0.80 kgf/cm2, 11.4 psi)

0.65 to 0.95 V

98.0 kPa (1.00 kgf/cm2, 14.2 psi)

0.9 to 1.2 V
Turbocharger pressure Condition Specified Condition
Engine speed (approximately 4600 rpm)

10 to 40 kPa (0.10 to 0.41 kgf/cm2, 1.5 to 5.8 psi)

Turbocharger Condition Specified Condition
Maximum axial play of turbine shaft 0.11 mm (0.0043 in.)
w/o EGR cooler
Manifold absolute pressure sensor Condition Tester connection Specified Condition
ECM output voltage T9-3 (VC (+)) - T9-1 (E2 (-)) 4.75 to 5.25 V
Applied vacuum - -
13.3 kPa (100 mmHg, 3.94 in.Hg) E7-28 (PIM) - E8-28 (E2) 0.1 to 0.4 V
26.6 kPa (199 mmHg, 7.85 in.Hg) 0.2 to 0.6 V
40 kPa (300 mmHg, 11.81 in.Hg) 0.4 to 0.8 V
Applied pressure - -

19. 6 kPa (0.20 kgf/cm2, 2.84 psi)

E7-28 (PIM) - E8-28 (E2) 0.1 to 0.4 V

39.2 kPa (0.40 kgf/cm2, 5.69 psi)

0.4 to 0.7 V

58.8 kPa (0.60 kgf/cm2, 8.53 psi)

0.7 to 1.0 V

78.5 kPa (0.80 kgf/cm2, 11.4 psi)

1.0 to 1.3 V

98.0 kPa (1.00 kgf/cm2, 14.2 psi)

1.3 to 1.6 V
Turbocharger pressure Condition Specified Condition
Engine speed (approximately 4600 rpm)

53 to 83 kPa (0.54 to 0.84 kgf/cm2, 7.6 to 12.0 psi)

Turbocharger Condition Specified Condition
Maximum axial play of turbine shaft 0.08 mm (0.0031 in.)
Maximum radial play of turbine shaft 0.110 mm (0.0043 in.)
Actuator and waste gate valve operation

114 kPa (1.16 kgf/cm2, 16.5 psi)