INPUT SHAFT INSPECTION
PROCEDURE
INSPECT INPUT SHAFT
-
Check the input shaft for wear and damage.
Using a dial indicator, measure the input shaft runout.
Maximum Runout
0.03 mm (0.00118 in.)
If the runout exceeds the maximum, replace the input shaft.
-
Using a micrometer, measure the outer diameter of the input shaft journal surface.
Standard
Measured Part
Outer Diameter mm (in.)
A
30.008 to 30.020 (1.1814 to 1.1819)
B
32.002 to 32.018 (1.2599 to 1.2605)
If the outer diameter is below the minimum, replace the input shaft.
-