LIGHTING (INT) SERVICE DATA

Table 1. PERSONAL LIGHT

Connector Condition

Tester Connection

Switch Condition

Specified Condition

Component without harnessconnected

1 (+B1) - 20 (GND)

Map light switch LH OFF

10 kΩ or higher

Map light switch LH ON

Below 1 Ω

Map light switch RH OFF

10 kΩ or higher

Map light switch RH ON

Below 1 Ω

1 (+B1) - 18 (CTY)

Courtesy switch OFF position

10 kΩ or higher

Courtesy switch DOOR position

Below 1 Ω

Table 2. FRONT DOOR COURTESY SWITCH

Connector Condition

Tester Connection

Switch Condition

Specified Condition

Component without harnessconnected

Terminal 1 - Switch body

Pushed

10 kΩ or higher

Not pushed

Below 1 Ω

Table 3. REAR DOOR COURTESY SWITCH

Connector Condition

Tester Connection

Switch Condition

Specified Condition

Component without harnessconnected

Terminal 1 - Switch body

Pushed

10 kΩ or higher

Not pushed

Below 1 Ω

Table 4. BACK DOOR COURTESY SWITCH (w/o Power Back Door)

Connector Condition

Tester Connection

Condition

Specified Condition

Component with harness connected

2 (ACT-) - 3 (D+)

Close

10 kΩ or higher

Open

Below 1 Ω

Table 5. BACK DOOR COURTESY SWITCH (w/ Power Back Door)

Connector Condition

Tester Connection

Condition

Specified Condition

Component with harness connected

3 (CLS) - 1 (E)

Open position

Below 1 Ω

Open position → Half-latch position

Below 1 Ω → 10 kΩ or higher

Half-latch position

10 kΩ or higher

Full-latch position

10 kΩ or higher

Overstroke position

10 kΩ or higher

1 (E) - 4 (CTY)

Open position

Below 1 Ω

Half-latch position

Below 1 Ω

Half-latch position → Full-latch position

Below 1 Ω → 10 kΩ or higher

Full-latch position

10 kΩ or higher

Overstroke position

10 kΩ or higher

2 (FSW) - 1 (E)

Open position

10 kΩ or higher

Open position → Half-latch position

10 kΩ or higher → Below 1 Ω → 10 kΩ or higher

Half-latch position

10 kΩ or higher

Half-latch position → Full-latch position

10 kΩ or higher → Below 1 Ω → 10 kΩ or higher

Full-latch position

10 kΩ or higher

Overstroke position

10 kΩ or higher

6 (OPN) - 1 (E)

Sector gear in neutral position

(Sector switch on)

Below 1 Ω

Sector gear not in neutral position

(Sector switch off)

10 kΩ or higher

Table 6. RELAY

Connector Condition

Tester Connection

Condition

Specified Condition

-

3 - 5

Battery voltage not applied to terminals 1 and 2

10 kΩ or higher

Battery voltage applied to terminals 1 and 2

Below 1 Ω