GENERATOR REMOVAL
PROCEDURE
PRECAUTION
Note:After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notice before proceeding with work.
DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
Note:When disconnecting the cable, some systems need to be initialized after the cable is reconnected.
REMOVE NO. 1 ENGINE COVER (w/ No. 1 Engine Cover)
REMOVE V-RIBBED BELT
REMOVE GENERATOR ASSEMBLY
-
Remove the terminal cap.
Disconnect the connector and 2 clamps.
Remove the nut and disconnect the wire harness from terminal B.
-
Fully loosen the bolt A.
Tip:The bolt A cannot be fully removed from the bracket.
Remove the bolt B and generator assembly.
-