| Manifold absolute pressure sensor | Condition | Tester Connection | Specified Condition | ||
| ECM output voltage | 3 VC (+) - 1 E2 (-) | 4.75 to 5.25 V | |||
| Applied vacuum | - | - | |||
| 13.3 kPa (100 mmHg, 3.94 in.Hg) | E27-5 (PIM +) - E27-14 (E2-) | 0.8 to 1.4 V | |||
| 26.6 kPa (199 mmHg, 7.85 in.Hg) | 0.5 to 1.0 V | ||||
| 40 kPa (300 mmHg, 11.81 in.Hg) | 0.3 to 0.9 V | ||||
| Applied pressure | - | - | |||
| 19.6 kPa (0.20 kgf/cm2, 2.84 psi) |
E27-5 (PIM +) - E27-14 (E2-) | 1.0 to 1.7 V | |||
| 39.2 kPa (0.40 kgf/cm2, 5.69 psi) |
1.3 to 1.9 V | ||||
| 58.8 kPa (0.60 kgf/cm2, 8.53 psi) |
1.5 to 2.2 V | ||||
| 78.5 kPa (0.80 kgf/cm2, 11.4 psi) |
1.8 to 2.4 V | ||||
| 98.0 kPa (1.00 kgf/cm2, 14.2 psi) |
2.1 to 2.7 V | ||||
| Turbocharger boost pressure | Standard pressure | 5 to 20 kPa (0.05 to 0.2 kgf/cm2, 0.7 to 2.9 psi) |
|||
| Turbocharger | Axial play of turbine shaft | Maximum axial play | 0.11 mm (0.0043 in.) | ||
| Vacuum switching valve (for Swirl Control Valve) | Condition | Tester connection | Specified Condition |
| 1 - 2 | 20 °C (68°F) | 33 to 39 Ω | |
| 1 - Body ground 2 - Body ground |
20 °C (68°F) | 10kΩ or higher | |
| Manifold absolute pressure sensor | Condition | Tester connection | Specified Condition |
| ECM output voltage | 3 (VC (+)) - 1 (E2 (-)) | 4.75 to 5.25 V | |
| Applied vacuum | - | - | |
| 13.3 kPa (100 mmHg, 3.94 in.Hg) | E7-28 (PIM (+)) - E8-28 (E2 (-)) | 0 to 0.3 V | |
| 26.6 kPa (199 mmHg, 7.85 in.Hg) | 0.1 to 0.4 V | ||
| 40 kPa (300 mmHg, 11.81 in.Hg) | 0.2 to 0.6 V | ||
| Applied pressure | - | - | |
| 19. 6 kPa (0.20 kgf/cm2, 2.84 psi) |
E7-28 (PIM (+)) - E8-28 (E2( -)) | 0.05 to 0.3 V | |
| 39.2 kPa (0.40 kgf/cm2, 5.69 psi) |
0.25 to 0.55 V | ||
| 58.8 kPa (0.60 kgf/cm2, 8.53 psi) |
0.45 to 0.75 V | ||
| 78.5 kPa (0.80 kgf/cm2, 11.4 psi) |
0.65 to 0.95 V | ||
| 98.0 kPa (1.00 kgf/cm2, 14.2 psi) |
0.9 to 1.2 V | ||
| Turbocharger pressure | Item | Condition | Specified Condition |
| (for Waste Gate Type Turbocharger) | Engine speed (4450 to 4750 rpm) | 53 to 83 kPa (0.54 to 0.84 kgf/cm2, 7.6 to 12.0 psi) |
|
| (for Variable Nozzle Vane Turbocharger) | 85 to 115 kPa (0.9 to 1.2 kgf/cm2, 12.3 to 17 psi) |
||
| Turbocharger | Item | Condition | Specified Condition |
| (for Waste Gate Type Turbocharger) | Maximum axial play of turbine shaft | 0.08 mm (0.0031 in.) | |
| Maximum radial play of turbine shaft | 0.110 mm (0.0043 in.) | ||
| Actuator and waste gate valve operation | 108 kPa (1.10 kgf/cm2, 16 psi) |
||
| (for Variable Nozzle Vane Turbocharger) | Maximum axial play of turbine shaft | 0.110 mm (0.00433 in.) |
| Vacuum switching valve (for Swirl Control Valve) (w/ Intercooler) |
Condition | Tester connection | Specified Condition |
| 1 - 2 | 20 °C (68°F) | 33 to 39 Ω | |
| 1 - Body ground 2 - Body ground |
20 °C (68°F) | 10kΩ or higher | |
| Manifold absolute pressure sensor | Condition | Tester connection | Specified Condition |
| (w/ Intercooler) | ECM output voltage | T9-3 (VC (+)) - T9-1 (E2 (-)) | 4.75 to 5.25 V |
| (w/o Intercooler) | 4.5 to 5.5 V | ||
| - | Applied vacuum | - | - |
| (w/ Intercooler) | 13.3 kPa (100 mmHg, 3.94 in.Hg) | E7-28 (PIM) - E8-28 (E2) | 0.0 to 0.3 V |
| 26.6 kPa (199 mmHg, 7.85 in.Hg) | 0.1 to 0.4 V | ||
| 40 kPa (300 mmHg, 11.81 in.Hg) | 0.3 to 0.6 V | ||
| (w/o Intercooler) | 13.3 kPa (100 mmHg, 3.94 in.Hg) | E7-28 (PIM) - E8-28 (E2) | 0.1 to 0.4 V |
| 26.6 kPa (199 mmHg, 7.85 in.Hg) | 0.2 to 0.6 V | ||
| 40 kPa (300 mmHg, 11.81 in.Hg) | 0.4 to 0.8 V | ||
| - | Applied pressure | - | - |
| (w/ Intercooler) | 19. 6 kPa (0.20 kgf/cm2, 2.84 psi) |
E7-28 (PIM) - E8-28 (E2) | 0.05 to 0.3 V |
| 39.2 kPa (0.40 kgf/cm2, 5.69 psi) |
0.25 to 0.55 V | ||
| 58.8 kPa (0.60 kgf/cm2, 8.53 psi) |
0.45 to 0.75 V | ||
| 78.5 kPa (0.80 kgf/cm2, 11.4 psi) |
0.65 to 0.95 V | ||
| 98.0 kPa (1.00 kgf/cm2, 14.2 psi) |
0.9 to 1.2 V | ||
| (w/o Intercooler) | 19. 6 kPa (0.20 kgf/cm2, 2.84 psi) |
E7-28 (PIM) - E8-28 (E2) | 0.1 to 0.4 V |
| 39.2 kPa (0.40 kgf/cm2, 5.69 psi) |
0.4 to 0.7 V | ||
| 58.8 kPa (0.60 kgf/cm2, 8.53 psi) |
0.7 to 1.0 V | ||
| 78.5 kPa (0.80 kgf/cm2, 11.4 psi) |
1.0 to 1.3 V | ||
| 98.0 kPa (1.00 kgf/cm2, 14.2 psi) |
1.3 to 1.6 V | ||
| Turbocharger pressure | Item | Condition | Specified Condition |
| (w/ Intercooler) | Engine speed (4450 to 4750 rpm) | 85 to 115 kPa (0.9 to 1.2 kgf/cm2, 12.3 to 17 psi) |
|
| (w/o Intercooler) | 53 to 83 kPa (0.54 to 0.84 kgf/cm2, 7.6 to 12.0 psi) |
||
| Turbocharger | Item | Condition | Specified Condition |
| (w/ Intercooler) | Maximum axial play of turbine shaft | 0.11 mm (0.00433 in.) | |
| (w/o Intercooler) | Maximum axial play of turbine shaft | 0.08 mm (0.0031 in.) | |
| Maximum radial play of turbine shaft | 0.110 mm (0.0043 in.) | ||
| Actuator and waste gate valve operation | 108 kPa (1.10 kgf/cm2, 16 psi) |