LUGGAGE COMPARTMENT DOOR OPENER MAIN SWITCH INSPECTION

PROCEDURE


  1. INSPECT LUGGAGE DOOR OPENING CANCEL SWITCH ASSEMBLY


    1. B005SG6C04
      *a

      Component without harness connected

      (Luggage Door Opening Cancel Switch Assembly)

      Check the resistance.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Switch Condition Specified Condition
        G74-2(B) - G74-1(L) Switch on Below 1 Ω
        G74-2(B) - G74-1(L) Switch off 10 kΩ or higher

        Tech Tips

        If the result is not as specified, replace the luggage door opening cancel switch assembly.