STARTER(for 1.6 kW Type) REMOVAL
PROCEDURE
PRECAUTION
Note:After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work.
DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
Note:When disconnecting the cable, some systems need to be initialized after the cable is reconnected.
Click hereClick hereClick hereClick hereClick hereClick here
DISCONNECT CABLE FROM POSITIVE BATTERY TERMINAL
REMOVE BATTERY CLAMP SUB-ASSEMBLY
-
Remove the bolt and loosen the nut.
Detach the 2 wire harness clamps.
Detach the hook of the battery clamp sub-assembly from the front battery bracket, and then remove the battery clamp sub-assembly.
-
REMOVE BATTERY INSULATOR
REMOVE BATTERY
REMOVE BATTERY TRAY
REMOVE FRONT BATTERY BRACKET
-
Remove the 4 bolts and front battery bracket.
-
REMOVE BATTERY BRACKET REINFORCEMENT
Remove the 2 bolts and battery bracket reinforcement.
REMOVE STARTER ASSEMBLY
-
Disconnect the starter connector and remove the terminal cap.
Remove the nut and disconnect the starter wire.
-
Remove the 2 bolts and starter assembly.
-