RELAY ON-VEHICLE INSPECTION
PROCEDURE
INSPECT ST RELAY
-
Check the resistance.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
3 - 5
Battery voltage not applied to terminals 1 and 2
10 kΩ or higher
Battery voltage applied to terminals 1 and 2
Below 1 Ω
If the result is not as specified, replace the ST relay.
-
INSPECT ST CUT RELAY (w/o Smart Entry and Start System)
-
Check the resistance.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
3 - 4
Battery voltage not applied between terminals 1 and 2
Below 1 Ω
If the result is not as specified, replace the ST CUT relay.
Tip:As the ST CUT relay is isolated from ground, the contacts of the ST CUT relay remain closed at all times.
-