HAZARD WARNING SWITCH INSPECTION
PROCEDURE
INSPECT HAZARD WARNING SIGNAL SWITCH ASSEMBLY (for LHD)
-
*a
Component without harness connected
(Hazard Warning Signal Switch Assembly)
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
4 (TB) - 1 (E)
Hazard warning signal switch off
10 kΩ or higher
Hazard warning signal switch on
Below 1 Ω
If the result is not as specified, replace the hazard warning signal switch assembly.
Illumination Inspection
Apply battery voltage to the hazard warning signal switch assembly and check that the switch illuminates.
OK
Condition
Specified Condition
Battery positive (+) → Terminal 3 (ILL+)
Battery negative (-) → Terminal 2 (ILL-)
Illuminates
If the result is not as specified, replace the hazard warning signal switch assembly.
-
INSPECT HAZARD WARNING SIGNAL SWITCH ASSEMBLY (for RHD)
-
*a
Component without harness connected
(Hazard Warning Signal Switch Assembly)
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
4 (TB) - 1 (E)
Hazard warning signal switch off
10 kΩ or higher
Hazard warning signal switch on
Below 1 Ω
If the result is not as specified, replace the hazard warning signal switch assembly.
Illumination Inspection
Apply battery voltage to the hazard warning signal switch assembly and check that the switch illuminates.
OK
Condition
Specified Condition
Battery positive (+) → Terminal 3 (ILL+)
Battery negative (-) → Terminal 2 (ILL-)
Illuminates
If the result is not as specified, replace the hazard warning signal switch assembly.
-