FUEL PUMP(w/ Canister Pump Module) INSPECTION
PROCEDURE
INSPECT FUEL PUMP
Check the resistance.
-
*a
Component without harness connected
(Fuel Pump)
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
0.2 to 3.0 Ω
If the result is not as specified, replace the fuel pump.
-
Check the fuel pump operation.
Connect the positive (+) lead of the battery to terminal 1 of the connector, and the negative (-) lead to terminal 2. Check that the fuel pump operates.
If the fuel pump does not operate, replace the fuel pump.
Note:These tests must be performed within 10 seconds to prevent the coil from burning out.
Keep the fuel pump as far away from the battery as possible.
Always turn the voltage on and off on the battery side, not the fuel pump side.