FUEL PUMP(w/ Canister Pump Module) INSPECTION

PROCEDURE

  1. INSPECT FUEL PUMP

    1. Check the resistance.

      1. A298970C03

        *a

        Component without harness connected

        (Fuel Pump)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance

        Tester Connection

        Condition

        Specified Condition

        1 - 2

        20°C (68°F)

        0.2 to 3.0 Ω

        If the result is not as specified, replace the fuel pump.

    2. Check the fuel pump operation.

      1. Connect the positive (+) lead of the battery to terminal 1 of the connector, and the negative (-) lead to terminal 2. Check that the fuel pump operates.

        If the fuel pump does not operate, replace the fuel pump.

        Note:
        • These tests must be performed within 10 seconds to prevent the coil from burning out.

        • Keep the fuel pump as far away from the battery as possible.

        • Always turn the voltage on and off on the battery side, not the fuel pump side.