AIR CONDITIONING PANEL(for Manual Air Conditioning System) INSPECTION
PROCEDURE
INSPECT HEATER CONTROL BASE (AIR INLET CONTROL SWITCH)
-
Disconnect the connector from the heater control base (air inlet control switch).
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Switch Condition
Specified Condition
3 (FRS) - 4 (REC)
Air inlet control switch FREE
Below 1 Ω
3 (FRS) - 4 (REC)
Air inlet control switch LOCK
10 kΩ or higher
Table 1. Text in Illustration *1
Component without harness connected
(Heater Control Base [Air Inlet Control Switch])
Check that the indicator light comes on.
Turn the heater control base (air inlet control switch) to LOCK.
Connect the positive (+) lead from the battery to terminal 2 and the negative (-) lead to terminal 4, and check that the indicator light comes on.
OK
The indicator light comes on.
If the result is not as specified, replace the heater control base (air inlet control switch).
-
INSPECT HEATER CONTROL (BLOWER SWITCH)
-
Disconnect the connector from the heater control (blower switch).
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Switch Condition
Specified Condition
4 (LO), 6 (HI), 9 (M1), 10 (M2) - 5 (E)
Blower switch OFF
10 kΩ or higher
4 (LO) - 5 (E)
Blower switch LO
Below 1 Ω
4 (LO), 9 (M1) - 5 (E)
Blower switch M1
Below 1 Ω
4 (LO), 10 (M2) - 5 (E)
Blower switch M2
Below 1 Ω
4 (LO), 6 (HI) - 5 (E)
Blower switch HI
Below 1 Ω
Check that the indicator light comes on.
Turn the heater control base (air inlet control switch) to LOCK.
Connect the positive (+) lead from the battery to terminal 2 and the negative (-) lead to terminal 4, and check that the indicator light comes on.
OK
The indicator light comes on.
Table 2. Text in Illustration *1
Component without harness connected
(Heater Control [Blower Switch])
If the result is not as specified, replace the heater control (blower switch).
-
INSPECT NO. 3 HEATER CONTROL
-
Disconnect the connector from the No. 3 heater control.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Switch Condition
Specified Condition
2 (B) - 3 (A/C)
No. 3 heater control (A/ C) LOCK
Below 1 Ω
2 (B) - 3 (A/C)
No. 3 heater control (A/ C) FREE
10 kΩ or higher
7 (B) - 8 (E) *1
No. 3 heater control (MAX HOT) ON
Below 1 Ω
7 (B) - 8 (E) *1
No. 3 heater control (MAX HOT) OFF
10 kΩ or higher
*1: w/ PTC Heater
Table 3. Text in Illustration *1
w/ PTC Heater
*2
Component without harness connected
(No. 3 Heater Control)
Check that the indicator light comes on.
Connect the positive (+) lead from the battery to terminal 3 and the negative (-) lead to terminal 4, and check that the indicator light comes on.
OK
The indicator light comes on.
If the result is not as specified, replace the No. 3 heater control.
-