INPUT SHAFT INSPECTION


  1. INSPECT SYNCHRONIZER RING NO.2


    1. B007OQR

      Apply gear oil to the cone of the input shaft, and check that it does not turn in either direction while pushing the synchronizer ring No.2.

      If it turns, replace the synchronizer ring.

    2. B007ONG

      Measure the clearance between the synchronizer ring No.2 and input shaft while pushing the synchronizer ring No.2 against the cone of the input shaft.

      Standard clearance
      0.70 to 1.70 mm (0.0276 to 0.0669 in.)

      If the clearance is not within the specified values, replace the synchronizer ring No.2 with a new one.