PROCEDURE
RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM
REMOVE PIPING CLAMP (for DENSO Made)
for Suction Hose Sub-assembly:
While pressing the end of the suction hose sub-assembly into the end of the suction pipe sub-assembly, use pliers to squeeze together both sides of the piping clamp until it breaks apart.
| *1 | Suction Pipe Sub-assembly | *2 | Suction Hose Sub-assembly |
| *3 | Piping Clamp | - | - |
| *a | Press In | - | - |
Note
If any foreign matter is adhered to the connecting part, brush it off or use compressed air to remove it.
Make sure that fragments of the piping clamp do not enter the piping.
Disconnect the suction hose sub-assembly.
Note
Clean off any foreign matter near the ends of the suction hose sub-assembly and suction pipe sub-assembly.
Remove the 2 O-rings from the suction hose sub-assembly.
Note
Wrap the open ends of the separated suction pipe sub-assembly and suction hose sub-assembly with vinyl tape to prevent entry of moisture and foreign matter.
Remove the piping clamp.
for Cooler Refrigerant Liquid Pipe A: