HAZARD WARNING SWITCH INSPECTION
PROCEDURE
INSPECT TELLTALE LIGHT ASSEMBLY (HAZARD WARNING SWITCH)
-
*a
Component without harness connected
(Telltale Light Assembly (Hazard Warning Switch))
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Switch Condition
Specified Condition
7 (TB) - 13 (E)
Hazard warning signal switch off
10 kΩ or higher
Hazard warning signal switch on
Below 1 Ω
If the result is not as specified, replace the telltale light assembly (hazard warning switch).
-