1AD-FTV INTAKE / EXHAUST SERVICE DATA

Table 1. INTAKE SYSTEM

Turbo pressure sensor

Standard Pressure (gauge pressure)

38 to 61 kPa (0.4 to 0.6 kgf/cm2, 5.5 to 8.8 psi)

Table 2. TURBOCHARGER SUB-ASSEMBLY

Tester Connection

Condition

Specified Condition

1 (M-) - 2 (M+)

Always

0.3 to 100 Ω

Table 3. EXHAUST PIPE

Compression spring

Front exhaust pipe assembly x Exhaust manifold

Minimum length: 41.5 mm (1.63 in.)

Front exhaust pipe assembly x Tail exhaust pipe assembly

Minimum length: 38.5 mm (1.52 in.)