RELAY ON-VEHICLE INSPECTION

PROCEDURE


  1. INSPECT HEATER RELAY (for Manual Air Conditioning System, Manual Cooler System)


    1. A01L9MCC01
      *a

      Component without harness connected

      (Heater Relay)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 4 Battery voltage is not applied between terminals 1 and 2 Below 1 Ω
      3 - 5 Battery voltage is not applied between terminals 1 and 2 10 kΩ or higher
      3 - 4 Battery voltage is applied between terminals 1 and 2 10 kΩ or higher
      3 - 5 Battery voltage is applied between terminals 1 and 2 Below 1 Ω

      If the result is not as specified, replace the heater relay.

  2. INSPECT MAGNET-CLUTCH RELAY (w/ Cooler System)


    1. A01SH31C11
      *a

      Component without harness connected

      (Magnet-clutch Relay)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 5 Battery voltage is not applied between terminals 1 and 2 10 kΩ or higher
      3 - 5 Battery voltage is applied between terminals 1 and 2 Below 1 Ω

      • If the result is not as specified, replace the magnet-clutch relay.

  3. INSPECT VISCOUS HEATER RELAY (w/ Viscous Heater)


    1. A01SH31C11
      *a

      Component without harness connected

      (Viscous Heater Relay)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 5 Battery voltage is not applied between terminals 1 and 2 10 kΩ or higher
      3 - 5 Battery voltage is applied between terminals 1 and 2 Below 1 Ω

      • If the result is not as specified, replace the viscous heater relay.

  4. INSPECT PTC HEATER RELAY(PTC HTR NO. 1) (w/ PTC Heater)


    1. A01LEM9C02
      *a

      Component without harness connected

      (PTC Heater Relay)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 5 Battery voltage is not applied between terminals 1 and 2 10 kΩ or higher
      3 - 5 Battery voltage is applied between terminals 1 and 2 Below 1 Ω

      • If the result is not as specified, replace the PTC heater relay (PTC HTR No. 1).

  5. INSPECT PTC HEATER RELAY(PTC HTR NO. 2, NO. 3) (w/ PTC Heater)


    1. A01SH31C11
      *a

      Component without harness connected

      (PTC Heater Relay)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 5 Battery voltage is not applied between terminals 1 and 2 10 kΩ or higher
      3 - 5 Battery voltage is applied between terminals 1 and 2 Below 1 Ω

      • If the result is not as specified, replace the PTC heater relay (PTC HTR No. 2, No. 3).