CHARGING SYSTEM Noise Occurs from V-ribbed Belt or Generator Assembly
| DTC Code | DTC Name |
|---|---|
| Noise Occurs from V-ribbed Belt or Generator Assembly |
PROCEDURE
CONFIRM PROBLEM SYMPTOM
Confirm the problem symptom.
Result
Symptom
Proceed to
Noise occurs from V-ribbed belt assembly
A
Noise occurs from generator assembly
B
B CHECK FOR NOISE WHEN ROTOR IS TURNING FREELYClick here
CHECK V-RIBBED BELT FOR WEAR
Check the V-ribbed belt for wear or damage.
OK
The V-ribbed belt is not worn or damaged.
Result
Result
OK
NG
CHECK GENERATOR WITH CLUTCH PULLEY FOR WEAR
Check the generator with clutch pulley grooves for wear or damage.
OK
The generator with clutch pulley grooves are not worn or damaged.
Result
Result
OK
NG
CHECK FOR NOISE WHILE CLUTCH PULLEY IS OPERATING
Start the engine and check the generator with clutch pulley for looseness.
OK
The generator with clutch pulley with clutch is not loose.
Result
Result
OK
NG
NG TIGHTEN GENERATOR WITH CLUTCH PULLEY TO SPECIFIED TORQUE
INSPECT GENERATOR WITH CLUTCH PULLEY (UNIT INSPECTION)
Remove the generator assembly.
Check the installation condition of the generator pulley cap.
OK
The generator pulley cap is not loose or missing.
Check for forming of particles due to friction (for dry type pulley) or grease leaks (for wet type pulley).
OK
There are no large amount of particles (for dry type pulley) or grease leaks (for wet type pulley).
Check the generator with clutch pulley for misalignment (interference with the generator assembly).
OK
The generator with clutch pulley is not misaligned (no interference with the generator assembly).
-
Turn the generator with clutch pulley clockwise and counterclockwise by hand and check for noise.
OK
Noise does not occur when turned in both directions.
Turn the generator with clutch pulley clockwise and counterclockwise by hand and visually check for runout.
OK
The generator with clutch pulley does not have runout.
-
Hold the generator rotor assembly (fan) in the generator assembly with a screwdriver, and check that the generator with clutch pulley locks when turned clockwise and turns freely when turned counterclockwise.
OK
The generator with clutch pulley locks when turned clockwise and turns freely when turned counterclockwise.
Result
Result
OK
NG
OK INSPECT PULLEY OTHER THAN GENERATOR ASSEMBLY PULLEY
CHECK FOR NOISE WHEN ROTOR IS TURNING FREELY
Perform a road test and check that noise does not occur when decelerating.
OK
Noise does not occur.
Stop the engine and check that generator with clutch pulley noise does not occur as the engine stops.
OK
Noise does not occur.
Result
Result
OK
NG
CHECK ENGAGEMENT OF GENERATOR WITH CLUTCH PULLEY
Remove the generator assembly.
Hold the generator rotor assembly (fan) in the generator assembly with a screwdriver, and check that the generator with clutch pulley locks when turned from counterclockwise (free turning direction) to clockwise (locking direction).
OK
The generator with clutch pulley locks.
Result
Result
OK
NG