EGR BYPASS VALVE SWITCHING VALVE INSTALLATION

PROCEDURE

  1. INSTALL EGR BYPASS VALVE SWITCHING VALVE

    1. Attach the claw and install the EGR bypass valve switching valve assembly.

    2. Connect the 2 vacuum hoses.

    3. Connect the EGR bypass valve switching valve assembly connector.

      1. Push on the EGR bypass valve switching valve assembly connector until the spring lock makes a sound and returns to its original position.

        Tip:

        It is not necessary to push the spring lock down when connecting the EGR bypass valve switching valve assembly connector.

  2. INSTALL NO. 1 ENGINE COVER