VACUUM REGULATING VALVE INSPECTION
PROCEDURE
INSPECT VACUUM REGULATING VALVE ASSEMBLY
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
11.1 to 12.5 Ω
If the result is not as specified, replace the vacuum regulating valve assembly.
Check the operation of the vacuum regulating valve assembly.
-
*a
Port (E)
*b
Port (F)
*c
Air
Using a vacuum pump, apply a vacuum of 67 kPa (503 mmHg, 19.8 in. Hg) to the port (F) and check that the vacuum regulating valve assembly operates normally.
Check that air flows from the filter when air is blown into the port (E).
Tip:When air is blown into the port (E), the vacuum of the port (F) decreases.
-
*a
Port (E)
*b
Port (F)
*c
Air
Apply battery voltage between the terminals, and check that air flows from the port (F) when air is blown into the port (E).
-