PRESSURE SENSOR INSPECTION

PROCEDURE


  1. INSPECT HEIGHT CONTROL PRESSURE SENSOR


    1. B005RYYC02
      *a

      Component without harness connected

      (Height control pressure sensor)

      Check the height control pressure sensor output voltage.

      Standard Voltage
      Tester Connection Condition Specified Condition
      L3-2 (PACC) - L3-3 (SHB) Apply 5 V between terminals 1 (SHG) and 3 (SHB). 0.5 to 4.5 V

      Tech Tips


      • If a stable power supply is not available, connect 4 nickel-metal hydride batteries (1.2 V each) or equivalent in series.

      • If the result is not as specified, replace the height control pressure sensor.