HEATED OXYGEN SENSOR REMOVAL

CAUTION / NOTICE / HINT

The necessary procedures (adjustment, calibration, initialization or registration) that must be performed after parts are removed, installed, or replaced during the heated oxygen sensor removal/installation are shown below.

Necessary Procedure After Parts Removed/Installed/Replaced
Replaced Part or Performed Procedure Necessary Procedures Effect/Inoperative Function when Necessary Procedure not Performed Link
Gas leak from exhaust system is repaired Inspection after repair
  • Poor idle, etc.

  • Engine start function, etc.

Click here

PROCEDURE


  1. REMOVE HEATED OXYGEN SENSOR


    1. B004IE2

      Disconnect the heated oxygen sensor connector.

    2. B004N9RN01

      Using SST, remove the heated oxygen sensor from the front exhaust pipe assembly (TWC: Rear Catalyst).

      SST
      09224-00012

      Note

      If the heated oxygen sensor has been struck or dropped, replace it.