AIR FUEL RATIO SENSOR INSPECTION
PROCEDURE
INSPECT AIR FUEL RATIO SENSOR
-
*A
for Bank 1
*B
for Bank 2
*a
Component without harness connected
(Air Fuel Ratio Sensor)
Measure the heater resistance according to the value(s) in the table below.
Standard Resistance (for Bank 1)
Tester Connection
Condition
Specified Condition
1 (HA1A) - 2 (+B)
20°C (68°F)
1.8 to 3.4 Ω
1 (HA1A) - 4 (A1A-)
Always
10 kΩ or higher
Standard Resistance (for Bank 2)
Tester Connection
Condition
Specified Condition
1 (HA2A) - 2 (+B)
20°C (68°F)
1.8 to 3.4 Ω
1 (HA2A) - 4 (A2A-)
Always
10 kΩ or higher
If the result is not as specified, replace the air fuel ratio sensor.
-