AUTOMATIC TRANSAXLE SYSTEM, Diagnostic DTC:P275613

DTC Code DTC Name
P275613 Torque Converter Clutch Pressure Control Solenoid Control Circuit Open

DESCRIPTION

Refer to DTC P27567F.

Click here

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory Note
P275613 Torque Converter Clutch Pressure Control Solenoid Control Circuit Open

1. Diagnosis Condition 2. Malfunction Status 3. Malfunction Time 4. Other


  1. The vehicle is being driven.

  2. An open or short in the solenoid (SLU) valve circuit is detected.

  3. 1 second

  4. 1-trip detection logic


  • Open or short in solenoid (SLU) valve circuit

  • Wiring harness connector

  • Transmission wire

  • Solenoid (SLU) valve

  • ECM

Comes on DTC stored

SAE Code:

P2759

MONITOR DESCRIPTION

When an open or short in the solenoid (SLU) valve circuit is detected, the ECM determines there is a malfunction, illuminates the MIL and stores a DTC.

WIRING DIAGRAM

B007ZT1E41

CAUTION / NOTICE / HINT

Note

Perform registration and/or initialization when parts related to the automatic transaxle are replaced.

Click here

Tech Tips

After performing repair, clear the DTCs and perform the following procedure to check that DTCs are not output.


  1. Perform the Lock-up Function inspection in Road Test.

    Click here

  2. Check for DTCs again.

    Click here

PROCEDURE


  1. CHECK HARNESS AND CONNECTOR (SOLENOID (SLU) VALVE CIRCUIT)


    1. Disconnect the D1 ECM connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      D1-3 (SLU+) - D1-2 (SLU-) 20°C (68°F) 5.0 to 5.6 Ω
      D1-3 (SLU+) - Body ground and other terminals Always 10 kΩ or higher
      D1-2 (SLU-) - Body ground and other terminals Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    OK
    NG
  2. CHECK HARNESS AND CONNECTOR (WIRING HARNESS CONNECTOR - ECM)


    1. Disconnect the D57 wiring harness connector connector.

    2. Disconnect the D1 ECM connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      D57-14 (SLU+) - D1-3 (SLU+) Always Below 1 Ω
      D57-5 (SLU-) - D1-2 (SLU-) Always Below 1 Ω
      D57-14 (SLU+) or D1-3 (SLU+) - Body ground and other terminals Always 10 kΩ or higher
      D57-5 (SLU-) or D1-2 (SLU-) - Body ground and other terminals Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    NG
    OK
  3. INSPECT TRANSMISSION WIRE (SOLENOID (SLU) VALVE)


    1. B00800AC08
      *a

      Component without harness connected

      (Transmission Wire)

      Remove the wiring harness connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      A-11 (SLU+) - A-5 (SLU-) 20°C (68°F) 5.0 to 5.6 Ω
      A-11 (SLU+) - Body ground and other terminals Always 10 kΩ or higher
      A-5 (SLU-) - Body ground and other terminals Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    OK
    NG
  4. INSPECT SOLENOID (SLU) VALVE


    1. B007XRMC14
      *1 Solenoid (SLU) Valve

      Remove the solenoid (SLU) valve.

      Click here

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω
    3. Connect a positive (+) lead with a 21 W bulb from the battery to terminal 1 and a negative (-) lead to terminal 2 of the solenoid valve connector. Check that the valve moves and makes an operating sound.

      OK
      Valve moves and makes an operating sound.
      Result
      Proceed to
      OK
      NG

    OK
    NG